FEATURED

HIGH BRIGHT DISPLAYS


                                 

 





Lost Password?
No account yet? Register

NEWSFLASH

 Active Image

Led signs & displays designed for Industrial applications:

 Active Image

  • Our low cost Led signs, displays & electronic scoreboards range from small to large.
  • Can be driven by our very low cost PLC which is extremely fast and easy to setup and install.
  • All networking and connectivity options available to interface with the led display.
  • Can be used in industrial settings, manufacturing as well as commercial for advertising, alarms, production information and anything else that needs communicating via a large or small led sign or display.
  • We even have sunlight-readable signs and high-bright or ultra-bright displays depending on your application.
  • More information is provided on our range of led signs, displays and electronic scoreboards by clicking on the link for a working example.  
 

Scrolling Newsflash

EZAutomation Australiasia supply and support a range of Touch screens, panels, HMIs, operator interfaces and panels, industrial computers and PCs, PLCs, LED signs and displays and more. Our service extends to a fully equipped workshop with on site experienced engineers to facilitate fast service, support on all warranty and repairs.

The EZAutomation products include a low cost range of touch screens and panels, including such specialised items as outdoor readable and high bright LED signs and displays and touch panels. We also supply a new remote access card which can be supplied or retro-fitted to our range of touch panels and screens. This module allows full control and viewing facilities of our products from anywhere in the world over the web.

Another feature of the EZAutomation range of operator interfaces and panels is the comprehensive range of connection options. We talk to all the major industrial networks including Ethernet, Devicenet, profibus and modbus plus. Our range of touch screens also come standard with serial interfaces and drivers for most PLCs on the market. 

 

Latest News

Active Image
Active Image
 

Home arrow Protocols Supported
Print E-mail

Our range of Touch screens, panel, operator interfaces, LED displays and PLCs have full connectivity options and can talk to most networks including Ethernet.
 
PLC Brand PLC Model Protocols Supported by EZPanel
Allen Bradley
MicroLogix 1000/1200/1500
DH485 (Direct to PLC, 1761-NET-AIC),
DF1 (Full Duplex),
DF1 (Half Duplex),
DF1 over Ethernet/IP (Universal Ethernet required, must use 1761-NET-ENI),
DeviceNet (option card required, slave node only)
SLC 500, 5/01, 5/02
DH485 (Direct to PLC, 1747-AIC, and 1761-NET-AIC)
SLC 5/03, 5/04, 5/05
DF1 (Full Duplex),
DF1 (Half Duplex),
DH485 (Direct to PLC, 1761-AIC, and 1761-NET-AIC),
DF1 over Ethernet/IP (Universal Ethernet required, SLC 5/03 and 5/04 must use 1761-NET-ENI),
Data Highway Plus (SLC 5/04, uses DH+ option board),
Remote IO (Uses DH+ option card)
DeviceNet (Option card required, slave node only)
PLC 2, 3, and 5
DF1 (Full Duplex, PLC 5 only),
DF1 over Ethernet/IP (PLC 5 only, Universal Ethernet required)
Data Highway Plus (Option card required)
Remote IO (uses DH+ option card),
DeviceNet (Option card required, slave node only)
Controllogix, Compactlogix
DF1 (Full Duplex, uses SLC 500 DF1 driver, special mapping required),
DH485 (uses SLC 500/MicroLogix driver, special mapping required, direct to PLC or 1761-NET-AIC),
Ethernet/IP (using Universal Ethernet required)
Ethernet/IP-IO (uses Ethernet/IP-IO option card),
Data Highway Plus (uses DH+ option card, special mapping required),
Remote IO (uses DH+ option card),
DeviceNet (option card required, slave node only)
Aromat
Aromat
Mewtocol COM
Control Techniques
Unidrive 2-Wire
ANSI
Note
: For Unidrive SP use Modbus RTU driver
Unidrive 4-Wire
Control Technology Corporation (CTC)
CTC2600
CTC Binary
CTC2700
CTC5100
Entivity (WinPLC)
H2-WinPLC Entivity (Think & Do)
V5.2 or later
Entivity (Think & Do) Modbus RTU (Serial Port)
EZAutomation
EZPLC
EZ-Protocol (RS-232 only)
General Electric
90/30
SNP-X,
SRTP Ethernet (Universal ethernet required),
Note: When communicating to the 90/70 PLC you must use a CMM711 Communications Coprocessor Module
90/70
Versamax
Idec
Idec
Computer Link
Mitsubishi
FX Series (all)
FX Protocol
CCLink
CC Link (Option card required)
Computer Link
Computer Link Dedicated Protocol Format 1
Modicon
984 CPU
Modbus RTU (RS-232/RS-485, Master Node Only),
Modbus Plus (Option card required)
Modbus TCP (Universal Ethernet required)
Quantum 113 CPU
AEG Modicon Micro Series 110
CPU: 311-xx, 411-xx, 512-xx, 612-xx
Compact
Momentum
Omron
C200
Host Link
C500
CQM1
CPM1, CPM2
DirectLogic
DL05
K-Sequence, DirectNet, Modbus (Koyo Addressing),
DL06
K-Sequence, DirectNet, Modbus (Koyo Addressing),
Modbus RTU
DL105
K-Sequence
DL205
D2-230
K-Sequence
D2-240
K-Sequence, DirectNet
D2-250/D2-250-1
K-Sequence, DirectNet, Modbus (Koyo Addressing)
D2-260
K-Sequence, DirectNet, Modbus (Koyo Addressing)
D2-240/250 w/DCM
DirectNet
DL305
D3-330/330P
DirectNet
D3-340
DirectNet
D3-350
K-Sequence, DirectNet, Modbus (Koyo Addressing)
D3-350 w/DCM
DirectNet
DL405
D4-430
K-Sequence, DirectNet
D4-440
K-Sequence, DirectNet
D4-450
K-Sequence, DirectNet, Modbus (Koyo Addressing)
All w/DCM
DirectNet
Siemens
S7 300/400 Series
3964R Protocol (Must use Siemens MPI-HMI Adapter)
Profibus (option card required, slave node only)
Square D Symax
300 Series CPU
Symax
400 Series CPU
Texas Instruments
TI5x5 Series
TBP (Transparent Byte Protocol)
NITP (Non-Intelligent Terminal Protocol)
TI505
TI545-1102
TI545-1104
Uni-Telway
Telemecanique TSX 37 Micro
UNI-TE (Version 1.1)
 
< Prev