Supported Protocols

Written by Administrator   
Tuesday, 22 November 2005 03:38

Our range of Industrial Touch Screens and LED Displays have full network connectivity. The below table sets out the various options>>

 

 

PLC Brand PLC Model Protocols Supported by EZPanel
Allen Bradley
MicroLogix 1000/1200/1500
DH485 (Direct to PLC, 1761-NET-AIC),
DF1 (Full Duplex),
DF1 (Half Duplex),
DF1 over Ethernet/IP (Universal Ethernet required, must use 1761-NET-ENI),
DeviceNet (option card required, slave node only)
SLC 500, 5/01, 5/02
DH485 (Direct to PLC, 1747-AIC, and 1761-NET-AIC)
SLC 5/03, 5/04, 5/05
DF1 (Full Duplex),
DF1 (Half Duplex),
DH485 (Direct to PLC, 1761-AIC, and 1761-NET-AIC),
DF1 over Ethernet/IP (Universal Ethernet required, SLC 5/03 and 5/04 must use 1761-NET-ENI),
Data Highway Plus (SLC 5/04, uses DH+ option board),
Remote IO (Uses DH+ option card)
DeviceNet (Option card required, slave node only)
PLC 2, 3, and 5
DF1 (Full Duplex, PLC 5 only),
DF1 over Ethernet/IP (PLC 5 only, Universal Ethernet required)
Data Highway Plus (Option card required)
Remote IO (uses DH+ option card),
DeviceNet (Option card required, slave node only)
Controllogix, Compactlogix
DF1 (Full Duplex, uses SLC 500 DF1 driver, special mapping required),
DH485 (uses SLC 500/MicroLogix driver, special mapping required, direct to PLC or 1761-NET-AIC),
Ethernet/IP (using Universal Ethernet required)
Ethernet/IP-IO (uses Ethernet/IP-IO option card),
Data Highway Plus (uses DH+ option card, special mapping required),
Remote IO (uses DH+ option card),
DeviceNet (option card required, slave node only)
Aromat
Aromat
Mewtocol COM
Control Techniques
Unidrive 2-Wire
ANSI
Note
: For Unidrive SP use Modbus RTU driver
Unidrive 4-Wire
Control Technology Corporation (CTC)
CTC2600
CTC Binary
CTC2700
CTC5100
Entivity (WinPLC)
H2-WinPLC Entivity (Think & Do)
V5.2 or later
Entivity (Think & Do) Modbus RTU (Serial Port)
EZAutomation
EZPLC
EZ-Protocol (RS-232 only)
General Electric
90/30
SNP-X,
SRTP Ethernet (Universal ethernet required),
Note: When communicating to the 90/70 PLC you must use a CMM711 Communications Coprocessor Module
90/70
Versamax
Idec
Idec
Computer Link
Mitsubishi
FX Series (all)
FX Protocol
CCLink
CC Link (Option card required)
Computer Link
Computer Link Dedicated Protocol Format 1
Modicon
984 CPU
Modbus RTU (RS-232/RS-485, Master Node Only),
Modbus Plus (Option card required)
Modbus TCP (Universal Ethernet required)
Quantum 113 CPU
AEG Modicon Micro Series 110
CPU: 311-xx, 411-xx, 512-xx, 612-xx
Compact
Momentum
Omron
C200
Host Link
C500
CQM1
CPM1, CPM2
DirectLogic
DL05
K-Sequence, DirectNet, Modbus (Koyo Addressing),
DL06
K-Sequence, DirectNet, Modbus (Koyo Addressing),
Modbus RTU
DL105
K-Sequence
DL205
D2-230
K-Sequence
D2-240
K-Sequence, DirectNet
D2-250/D2-250-1
K-Sequence, DirectNet, Modbus (Koyo Addressing)
D2-260
K-Sequence, DirectNet, Modbus (Koyo Addressing)
D2-240/250 w/DCM
DirectNet
DL305
D3-330/330P
DirectNet
D3-340
DirectNet
D3-350
K-Sequence, DirectNet, Modbus (Koyo Addressing)
D3-350 w/DCM
DirectNet
DL405
D4-430
K-Sequence, DirectNet
D4-440
K-Sequence, DirectNet
D4-450
K-Sequence, DirectNet, Modbus (Koyo Addressing)
All w/DCM
DirectNet
Siemens
S7 300/400 Series
3964R Protocol (Must use Siemens MPI-HMI Adapter)
Profibus (option card required, slave node only)
Square D Symax
300 Series CPU
Symax
400 Series CPU
Texas Instruments
TI5x5 Series
TBP (Transparent Byte Protocol)
NITP (Non-Intelligent Terminal Protocol)
TI505
TI545-1102
TI545-1104
Uni-Telway
Telemecanique TSX 37 Micro
UNI-TE (Version 1.1)